ESD wrist straps and grounding: a complete kit for a production line

PRIMEAG supplies ESD wrist straps, heel straps, ground cords and grounding sockets from VND 12,000 (ex 8% VAT), in stock and delivered in 24–48 hours in Ho Chi Minh City, Binh Duong and Dong Nai. The wrist strap cord has a 1 MΩ resistor, and total person-to-ground resistance is < 3.5×10⁷ Ω per ANSI/ESD S20.20.

In short: from VND 12,000 · EW-18 wrist strap with 1.8 m coiled cord, 1 MΩ resistor · inner surface < 10⁵ Ω, outer surface > 10⁷ Ω (ANSI/ESD S1.1) · person-to-ground < 3.5×10⁷ Ω · in stock, 24–48 hours · broken cords replaced free within 3 months.
PRIMEAG EW-18 ESD wrist strap with coiled cord
EW-18 ESD wrist strap with coiled cord.

What an ESD workstation needs

ComponentRoleRequirement
Wrist strap + coiled cordGrounds the seated operator1 MΩ resistor in the cord; person-to-ground < 3.5×10⁷ Ω
Heel strapGrounds walking personnel through the ESD floorPerson–footwear–floor < 1×10⁹ Ω (ANSI/ESD STM97.1)
Grounding socket / snap on the benchPlug-in point for wrist straps, connection for the bench matConnected to the common ground point
Bench mat ground cordGrounds the ESD rubber mat0.5 mm² cord, 1 MΩ resistor
Common ground pointBrings all of the station’s cords to one pointConnected to the factory’s equipment ground

Common audit findings

  • Wrist strap worn loose or over the sleeve — the inner surface does not touch the skin and the person-to-ground reading exceeds the limit.
  • Coiled cord broken inside the plastic sheath — looks normal but is open-circuit; check at the start of each shift with a wrist strap tester.
  • Bench mat and wrist strap connected to two different ground points — potential difference between the person and the work surface.

Not sure your current grounding system passes? PRIMEAG offers a free on-site ESD resistance test in Ho Chi Minh City, Binh Duong and Dong Nai and sends a report of readings by location. New PRIMEAG workbenches already come with a grounding snap and ground cord: see ESD workbenches.

Frequently asked questions

How much does an ESD wrist strap cost?

From VND 12,000 each ex 8% VAT, depending on cord and plug type. In stock, delivered in 24–48 hours in Ho Chi Minh City, Binh Duong and Dong Nai; lead time for large quantities is confirmed with the quotation.

Why must the wrist strap cord have a 1 MΩ resistor?

To discharge static in a controlled way and to limit current if the wearer accidentally touches a live source; connecting directly to ground without a resistor is unsafe.

How often should wrist straps be replaced?

When the start-of-shift tester shows a fail or the cord is broken. PRIMEAG replaces broken cords free within 3 months.

Do you sell a complete kit for a production line?

Yes. Send the number of workstations and PRIMEAG will quote a complete set of wrist straps, grounding sockets and ground cords within 30 minutes.

Quotation within 30 minutesBook a free ESD test

Updated: 21/10/2026 — PRIMEAG Technical Team

PRIMEAG · +84 906 108 292 (Zalo) · info@primeag.vn · Mon–Sat 8:00–17:00 (GMT+7).