Stocked item: delivered in 1–2 working days in Ho Chi Minh City, Binh Duong and Dong Nai; free delivery for orders from VND 20,000,000; defective items exchanged within 7 days. Shipping & return policy
Product code: MEASURE · Specification: Measuring and inspection equipment (electronic scales, magnifiers, calipers, barcode scanners)
Measuring & Inspection Equipment
Common specifications: bench clamp magnifier, thermo-hygrometer, 150 mm caliper.
Delivery: stocked items are delivered in 24–48 hours (Ho Chi Minh City, Binh Duong, Dong Nai); scales and printers 5–7 days; availability confirmed with the quotation.
Scales: 0.01 g precision balances (component counting, weighing solder paste), 30/60/150 kg bench scales (warehouse), dial scales. Viewing: 5D/8D bench clamp magnifiers with LED ring light, head-mounted magnifiers, 7–45× stereo microscopes for solder joints, hand-held magnifiers. Mechanical measurement: 150/200/300 mm digital calipers, micrometers, dial indicators, granite bases, gauges, master pins (Mitutoyo/Insize). Environment: cleanroom thermo-hygrometers, temperature pens, wood moisture meters, clarity meters. Electrical: multimeters, clamp meters, LCR meters. Barcode: Zebra/Honeywell corded/cordless scanners, Brother/Zebra label printers, component counters.
| Group | Model / specification |
|---|---|
| Scales | Ohaus/Shinko 0.01 g × 500 g; bench scales 30–150 kg; dial scale 30 kg |
| Magnifiers / microscopes | Bench clamp 5D/8D LED; head-mounted; stereo microscope 7–45× |
| Mechanical measurement | Calipers 150–300 mm; micrometer 0–25; dial indicator 0.01; granite base 300×300 |
| Environment | Wall-mounted/desktop thermo-hygrometers; temperature pens; wood moisture meters |
| Electrical | Kyoritsu/Hioki multimeters; clamp meters; LCR |
| Barcode | Zebra DS2208, Honeywell 1250g; TSC/Zebra printers; reel counters |
MOQ 1; calibration supplied on request.
FAQ
– What dioptre magnifier do I need? — 5D (2.25×) for long sessions; 8D (3×) for inspecting small solder joints.
– Do the scales come with a calibration certificate? — Yes, PRIMEAG arranges 12-month calibration on your behalf.
Magnifiers: what is the difference between “D” and “×”?
The “D” (dioptre) is the optical power of the lens. Nominal magnification is calculated with the formula M = D/4 + 1, based on a conventional near point of the eye of 25 cm. Therefore:
| Dioptre | Nominal magnification | Used for |
|---|---|---|
| 3D | 1.75× | Reading labels, prolonged visual inspection |
| 5D | 2.25× | Visual inspection, assembly for many hours |
| 8D | 3× | Inspecting small solder joints |
Actual magnification depends on where the lens is held and on the user’s eyes. The stronger a simple magnifier, the narrower the field of view and the greater the edge distortion; when a stable magnification above about 10× is needed (IC leads, cracks), switch to a stereo microscope.
Calipers: how accurate are they really?
- A typical 150 mm digital caliper has a resolution of 0.01 mm but an accuracy of about ±0.02 mm; longer calipers are less accurate — about ±0.03 mm for 100–200 mm and ±0.04 mm for 200–300 mm. Do not confuse the decimal places on the display with accuracy.
- Four measuring modes: outside (large jaws), inside (small jaws), depth (depth rod), step (end face of the caliper).
- Measuring force affects the result: squeezing too hard gives a smaller reading, too lightly a larger one. Micrometers have a ratchet that limits the force, so they repeat better.
- Check the zero before measuring: close the jaws, wipe them clean, set to 0. A caliper that has been dropped or knocked may no longer return to zero — it must be sent for calibration or repair.
- Digital calipers are sensitive to oil, coolant and dust; mechanical (vernier) calipers are robust and need no battery but are harder to read.
Electronic scales: what causes errors
- Draughts and airflow: 0.01 g balances are affected by air-conditioning and fans — use a draught shield and do not place them under an air outlet.
- Temperature: the item being weighed must be at room temperature; hot items create convection currents, cold items collect condensation and cause errors.
- Static electricity: plastic cups, PS trays and reels build up charge that creates an attractive force with the scale — the reading keeps jumping. Use metal trays, ESD trays, or an ionizer (code EI) to neutralise before weighing.
- Vibration, uneven surfaces: the scale must be levelled with its bubble level and placed on a rigid surface.
- Electronic scales must be recalibrated at the place of installation, because gravitational acceleration varies with location; after that, check periodically with traceable reference weights.
Calibration and legal verification
- Quality management systems (ISO 9001, IATF 16949) require measuring equipment used for product acceptance to have traceable calibration to national/international standards, a status label and records.
- In Vietnam, scales used for trade and for the handover of goods are subject to legal verification under metrology law (check against the current list of measuring instruments requiring verification); scales used internally (component counting, process checks) are usually calibrated at intervals set by the plant itself — typically 12 months.
- Between calibrations, run quick daily/weekly checks with reference weights, gauge blocks and master pins, and record them in a log.
Using measuring equipment in ESD areas
- The plastic housings of digital calipers, barcode scanners and scales are insulators. Do not place them close to bare components; in highly sensitive areas choose equipment with ESD housings or use an ionizer.
- Barcode scanners and label printers placed on an ESD bench should have properly earthed power cords.
Common mistakes
- Treating resolution as accuracy.
- Not re-zeroing; measuring parts that still have burrs or are oily.
- Weighing goods in charged plastic trays or under an air-conditioning outlet.
- Still using equipment that is overdue for calibration to make pass/fail decisions.
Technical references
- Wikipedia – Magnifying glass (dioptre – magnification formula)
- Wikipedia – Calipers (accuracy, zero point)
- Wikipedia – Weighing scale (sources of error, calibration)
- ESDA – Fundamentals of ESD, Part 2: Principles of ESD Control
Price: from 180,000 VND (excl. 8% VAT).
REQUEST A QUOTE: send the quantity and specifications you need — PRIMEAG quotes within 30 minutes.
Hotline/Zalo +84 906 108 292 · info@primeag.vn
Written by the PRIMEAG engineering team.
Related guides:Missing Screws in Flat-Pack Furniture Cartons: Bagging Bench, Divided…Fabric Rolls Crushed, Moldy or Mixed Shade Lots: Off-Floor…Calipers and Micrometers Reading Wrong Within Calibration: Causes and…
Updated: 2026-10-24
Giao tận nhà máy TP.HCM, Bình Dương, Đồng Nai, Long An, Tây Ninh · Kèm biên bản đo điện trở ESD theo lô · Hotline 0906 108 292