Stocked item: delivered in 1–2 working days in Ho Chi Minh City, Binh Duong and Dong Nai; free delivery for orders from VND 20,000,000; defective items exchanged within 7 days. Shipping & return policy

Product code: EI-701 · Specification: model 701 / 701+ / 701+NET, 1 fan head, 120 CFM, working distance 300–900 mm
Single-fan benchtop DC ionizing blower (701 / 701+ / 701+NET)
Delivery: made to order, 7–15 days; quantity and lead time confirmed with the quotation.
Looking for a benchtop ionizer for a single ESD workstation in Vietnam? The 701 is a single-fan DC benchtop ionizing blower with a 175×220×75 mm aluminium body, weighing 1.5 kg. Place it on the bench or a shelf and aim the airflow at one operator’s work area: repair benches, test benches, packing benches, air shower booths.
Available in 3 versions: 701 (no alarm), 701+ (automatic alarm), 701+NET (alarm + network connection). Stepless fan speed adjustment; front and rear grilles are removable for cleaning.
Technical specifications
| Versions | 701: no alarm · 701+: automatic alarm · 701+NET: automatic alarm + network connection |
|---|---|
| Ionization method | Corona discharge |
| Ion emitter voltage | Max. ±4,500 V |
| Ion balance adjustment | Manual |
| Discharge time | ≤ 2.0 s (±1,000 V → ±100 V, 300 mm from the air outlet) |
| Ion balance | ≤ ±10 V |
| Max. airflow | 120 CFM |
| Current consumption | 0.05 A (fan at maximum speed) |
| Working distance | 300–900 mm |
| Noise level | 35–44 dB |
| Ozone concentration | ≤ 0.002 ppm |
| Power supply | AC 220 V ±15 %/50 Hz or AC 110 V ±15 %/60 Hz |
| Operating environment | 0–50 °C; 20–85 %RH |
| Body material | Aluminium sheet |
| Colour | Grey-white + sky blue (plastic) |
| Weight | 1.5 kg |
| Dimensions | W175 × H220 × D75 mm |
Data according to the manufacturer’s catalogue.
When to choose the single-fan benchtop ionizing blower
- One workstation, airflow needs to reach far enough (up to 900 mm) → 701. Mounted close to a machine or microscope, tight space → mini ionizer (700).
- Long bench or 2 operators side by side → two-fan ionizing bar (702): 160 CFM, working distance up to 1,400 mm, balance ≤ ±5 V.
- Want to drop the manual needle-cleaning schedule → self-cleaning single-fan ionizer (711).
- Choosing the version: 701 when you have a periodic verification schedule; 701+ when the unit needs to raise its own alarm; 701+NET when the alarm signal must go to a network monitoring system.
Verification and maintenance
- Measure ion balance and discharge time with a charged plate monitor (CPM) at the actual distance where the product sits in front of the blower; check periodically (6 months recommended) and re-measure after every cleaning or emitter needle replacement.
- Emitter needles are consumables: clean them weekly with an IPA-moistened cotton swab with the power off, never touch the needles with bare hands; clean the intake grille to maintain airflow.
- An ionizer does not replace wrist straps, mats or flooring: grounding remains the primary measure for conductors and people; ionization is for insulators that cannot be removed (plastic housings, glass, films, trays).
Ordering
Send the model (701 / 701+ / 701+NET), quantity, required supply voltage (220 V or 110 V) and a description of the mounting position (bench, conveyor, inside a machine, distance to the product) so PRIMEAG can select the right size. To buy exactly the type you already use: send a photo of the unit’s label and of the mounting position.
Delivery: made to order, 7–15 days; quantity and lead time confirmed with the quotation.
Quotation within 30 minutes · Hotline/Zalo +84 906 108 292 · email info@primeag.vn · Mon – Sat, 8:00–17:00.
English: benchtop ionizer, ionizing blower, single-fan ionizer
한국어: 탁상형 이오나이저, 정전기 제거 송풍기
日本語: 卓上イオナイザー, 除電ブロワー
Frequently asked questions
701 vs 701+ vs 701+NET – which benchtop ionizer should I buy?
The static-neutralizing specifications are identical; they differ in function: 701 has no alarm, 701+ has an automatic alarm, 701+NET has an automatic alarm and network connection.
How far from the product should a benchtop ionizer be placed?
Working distance is 300–900 mm. The discharge time of ≤ 2.0 s is measured at 300 mm; place the unit close, aim it at the work area and do not let trays or monitors block the airflow.
How often does an ESD ionizer need to be checked?
Clean the needles weekly; measure ion balance and discharge time periodically (6 months recommended) with a CPM charged plate monitor, and re-measure after every cleaning or needle replacement.
See the overview page ESD ionizing blowers · same family: Mini ESD ionizing blower, Two-fan ESD ionizing bar blower, Self-cleaning single-fan ESD ionizing blower · guide: how to choose an ionizing blower, ionizing gun or ionizing bar.
Price: from 803,000 VND (excl. 8% VAT).
REQUEST A QUOTE: send the quantity and specifications you need — PRIMEAG quotes within 30 minutes.
Hotline/Zalo +84 906 108 292 · info@primeag.vn
Written by the PRIMEAG engineering team.
Related guides:Ionizer Balance Beyond ±35 V: Causes, Emitter Pin Cleaning…ESD Supplies for Panasonic, Fuji and Yamaha SMT Lines:…Ionizing Blower, Ion Gun or Ion Bar: When You…
Related products:Mini ESD Ionizing Blower 700 with High-Voltage Controller1-Fan Self-Cleaning ESD Ionizer 7112-Fan Self-Cleaning ESD Ionizer Bar 7123-Fan Self-Cleaning ESD Ionizer Bar 713
Updated: 2026-10-24