Stocked item: delivered in 1–2 working days in Ho Chi Minh City, Binh Duong and Dong Nai; free delivery for orders from VND 20,000,000; defective items exchanged within 7 days. Shipping & return policy

Product code: EI-711 · Specification: model 711, 1 fan, automatic emitter cleaning, neutralizing area 750 × 300 mm, DC 15 V supply
Single-fan DC ionizer with automatic emitter cleaning
Delivery: ordered item, 7–15 days; quantity and lead time are confirmed with the quotation.
Want a benchtop ESD ionizer for your Vietnam factory that needs no manual needle cleaning? The 711 is a new-generation single-fan DC ionizer that cleans its emitter needles automatically at power-on and once every 24 hours — no manual emitter cleaning required. Compact body 177 × 65.4 × 201.5 mm, 0.85 kg, powered by a separate DC 15 V adapter, 9 W.
Neutralizing area 750 × 300 mm, discharge ≤ 2 s and balance ≤ |±10 V| measured 300 mm from the air outlet. For electronics, optoelectronics and semiconductors; can be mounted at an angle on equipment frames.
Technical specifications
| Input voltage | 15 V (adapter: input 100–240 V 50/60 Hz, output DC 15 V 2,000 mA) |
|---|---|
| Power | 9 W |
| Ion balance | ≤ |±10 V| (300 mm directly in front of the air outlet) |
| Discharge time | ≤ 2 s (300 mm directly in front of the air outlet) |
| Neutralizing area | 750 × 300 mm (L × W) |
| Airflow | ≤ 89.1 CFM |
| Noise | ≤ 43 dB (1 m from the air outlet) |
| Ozone | ≤ 0.05 ppm (150 mm from the air outlet) |
| Emitter cleaning | Automatic at power-on and every 24 hours |
| Fan | Steplessly adjustable speed; removable front and rear grilles |
| Operating environment | 0–50 °C; 30–70 %RH |
| Dimensions | 177 × 65.4 × 201.5 mm (L × W × H) |
| Weight | Net 0.85 kg; gross 1.35 kg (incl. adapter and packaging) |
| Warranty | 1 year |
| Certification | CE |
Data according to the manufacturer’s catalogue.
When to choose the 1-fan self-cleaning ionizer
- You do not want to depend on a weekly emitter-cleaning schedule, or the ionizer is mounted where it is hard to reach → 711.
- Need a longer air throw (up to 900 mm) and versions with alarm and network connection → 1-fan benchtop ionizer (701 / 701+ / 701+NET); in exchange, emitters must be cleaned manually.
- Wider area, hung above a conveyor → 2-fan self-cleaning ionizer (712), neutralizing area 600 × 300 × 750 mm, direct AC supply.
- Ozone of the 711 is ≤ 0.05 ppm at 150 mm, of the 700–703 series ≤ 0.002 ppm; both are below the OSHA limit of 0.1 ppm (8-hour average), but avoid placing many ionizing devices in a closed, unventilated room.
Testing and maintenance
- Measure ion balance and discharge time with a charged plate monitor (CPM) at the actual distance of the product in front of the ionizer; check periodically (every 6 months recommended) and re-measure after every cleaning or emitter replacement.
- Emitters self-clean at power-on and every 24 hours; still clean the front and rear grilles periodically to maintain airflow.
- An ionizer does not replace wrist straps, mats or ESD flooring: grounding remains the primary measure for conductors and people; ionization is for insulators that cannot be removed (plastic housings, glass, films, trays).
Ordering
Send the model (711), quantity and a description of the mounting position (bench, conveyor, inside a machine, distance to the product) so PRIMEAG can select the right size. To buy the same type you already use: send a photo of the unit’s label and of the mounting position.
Delivery: ordered item, 7–15 days; quantity and lead time are confirmed with the quotation.
Quotation within 30 minutes · Hotline/Zalo +84 906 108 292 · email info@primeag.vn · Mon–Sat, 8:00–17:00.
English: self-cleaning ionizer, auto emitter cleaning ionizing blower
한국어: 자동 청소 이오나이저, 정전기 제거 송풍기
日本語: 自動清掃イオナイザー, 除電ファン
Frequently asked questions
Does self-cleaning mean the ionizer needs no maintenance?
Not quite. The emitters are cleaned automatically at power-on and every 24 hours, but you still need to clean the front and rear grilles and periodically measure balance and discharge time with a charged plate monitor.
What power supply does the 711 ionizer use?
A separate adapter: input 100–240 V 50/60 Hz, output DC 15 V 2,000 mA; unit power 9 W.
How is the 750 × 300 mm neutralizing area measured?
It is the neutralizing area stated in the catalogue; discharge time ≤ 2 s and balance ≤ |±10 V| are measured 300 mm directly in front of the air outlet.
See the overview page ESD ionizing blowers · same group: 2-fan self-cleaning ESD ionizer, 1-fan benchtop ESD ionizer, Mini ESD ionizer · guide: how to choose an ionizing blower, ionizing gun or ionizing bar.
Price: from 3,142,000 VND (excl. 8% VAT).
REQUEST A QUOTE: send the quantity and specifications you need — PRIMEAG quotes within 30 minutes.
Hotline/Zalo +84 906 108 292 · info@primeag.vn
Written by the PRIMEAG engineering team.
Related guides:Ionizer Balance Beyond ±35 V: Causes, Emitter Pin Cleaning…Ionizing Blower, Ion Gun or Ion Bar: When You…Analytical Balance Drifting from Static? Ionizer Fix for Weighing…
Related products:Single-Fan Benchtop ESD Ionizing Blower 701 / 701+ /…Mini ESD Ionizing Blower 700 with High-Voltage Controller2-Fan Self-Cleaning ESD Ionizer Bar 7123-Fan Self-Cleaning ESD Ionizer Bar 713
Updated: 2026-10-24
Giao tận nhà máy TP.HCM, Bình Dương, Đồng Nai, Long An, Tây Ninh · Kèm biên bản đo điện trở ESD theo lô · Hotline 0906 108 292
