Stocked item: delivered in 1–2 working days in Ho Chi Minh City, Binh Duong and Dong Nai; free delivery for orders from VND 20,000,000; defective items exchanged within 7 days. Shipping & return policy

Product code: EI-712 · Specification: model 712, 2-fan bar type, automatic emitter cleaning, neutralizing area 600 × 300 × 750 mm
Two-fan DC ionizer bar with automatic emitter cleaning
Delivery: ordered item, 7–15 days; quantity and lead time are confirmed with the quotation.
Need an overhead ionizer for a conveyor or machine frame in your Vietnam factory? The 712 is a 2-fan DC bar ionizer that cleans its emitter needles automatically at power-on and once every 24 hours. Powder-coated aluminium body 640 × 175 × 118 mm, supplied with an L-bracket for hanging above a conveyor or mounting on a machine frame.
Neutralizing area 600 × 300 × 750 mm, tungsten alloy emitters, direct AC 220 V or 110 V supply, power < 15 W.
Technical specifications
| Input voltage | AC 220 V/50 Hz or 110 V/60 Hz |
|---|---|
| Power | < 15 W |
| Operating voltage | ±DC 4,000–7,000 V |
| Ion generation | Steady-state DC |
| Emitter | Tungsten alloy |
| Discharge structure | Discharge tube, non-contact (electrically isolated) coupling |
| Ion outlets | 2 independent outlets, steplessly adjustable fan speed |
| Neutralizing area | 600 × 300 × 750 mm (L × W × H) |
| Discharge time | ≤ 3 s (450 mm vertically from the centre of the air outlet) |
| Ion balance | −15 V to +15 V (450 mm vertically from the centre of the air outlet) |
| Emitter cleaning | Automatic at power-on and every 24 hours |
| Indicator | Power lamp on: normal operation |
| Noise | ≤ 55 dB (1 m from the air outlet) |
| Airflow | ≤ 2 × 89.1 CFM |
| Ozone | ≤ 0.05 ppm (150 mm from the air outlet) |
| Operating environment | 0–50 °C; 30–70 %RH |
| Dimensions | 640 × 175 × 118 mm (L × W × H) |
| Housing | Powder-coated aluminium |
| Mounting accessories | 1 powder-coated aluminium L-bracket set; 1 pair of M6×12 thumb-screw knobs |
| Weight | Net 2,450 g (incl. power cord, bracket, accessories); gross 3,650 g |
| Warranty | 1 year |
| Certification | CE |
Data according to the manufacturer’s catalogue.
When to choose the 2-fan self-cleaning ionizer
- A single small workstation → 1-fan self-cleaning ionizer (711).
- Wider conveyors or benches → 713 (3 fans, 800 mm area) or 714 (4 fans, 1,060 mm area).
- Compared with the 2-fan ionizing bar 702: the 712 self-cleans its emitters and has an L-bracket; the 702 has balance ≤ ±5 V (measured at 300 mm) and versions with alarm and network connection. The two series are measured at different distances (450 mm and 300 mm), so the figures cannot be compared directly.
Testing and maintenance
- Measure ion balance and discharge time with a charged plate monitor (CPM) at the actual distance of the product in front of the ionizer; check periodically (every 6 months recommended) and re-measure after every cleaning or emitter replacement.
- Emitters self-clean at power-on and every 24 hours; still clean the front and rear grilles periodically to maintain airflow.
- An ionizer does not replace wrist straps, mats or ESD flooring: grounding remains the primary measure for conductors and people; ionization is for insulators that cannot be removed (plastic housings, glass, films, trays).
Ordering
Send the model (712), quantity, required supply voltage (220 V or 110 V) and a description of the mounting position (bench, conveyor, inside a machine, distance to the product) so PRIMEAG can select the right size. To buy the same type you already use: send a photo of the unit’s label and of the mounting position.
Delivery: ordered item, 7–15 days; quantity and lead time are confirmed with the quotation.
Quotation within 30 minutes · Hotline/Zalo +84 906 108 292 · email info@primeag.vn · Mon–Sat, 8:00–17:00.
English: self-cleaning ionizer bar, 2-fan overhead ionizer
한국어: 자동 청소 바형 이오나이저
日本語: 自動清掃バー型イオナイザー
Frequently asked questions
How is the 712 ionizer bar mounted?
It comes with 1 powder-coated aluminium L-bracket set and 1 pair of M6×12 thumb-screw knobs; it is usually hung above the conveyor or bench, blowing down onto the product area.
Is ±15 V balance worse than the ±5 V of the 702?
The two figures are measured at different distances: the 712 at 450 mm from the centre of the air outlet, the 702 at 300 mm. Your plant should measure at the actual product position with a charged plate monitor and compare against the acceptance value in your ESD control plan.
Do the emitters still need manual cleaning?
The emitters self-clean at power-on and every 24 hours; still clean the front and rear grilles periodically.
See the overview page ESD ionizing blowers · same group: 1-fan self-cleaning ESD ionizer, 3-fan self-cleaning ESD ionizer, 2-fan ESD ionizing bar · guide: how to choose an ionizing blower, ionizing gun or ionizing bar.
Price: from 2,759,000 VND (excl. 8% VAT).
REQUEST A QUOTE: send the quantity and specifications you need — PRIMEAG quotes within 30 minutes.
Hotline/Zalo +84 906 108 292 · info@primeag.vn
Written by the PRIMEAG engineering team.
Related guides:Ionizer Balance Beyond ±35 V: Causes, Emitter Pin Cleaning…Ionizing Blower, Ion Gun or Ion Bar: When You…Analytical Balance Drifting from Static? Ionizer Fix for Weighing…
Related products:Single-Fan Benchtop ESD Ionizing Blower 701 / 701+ /…Mini ESD Ionizing Blower 700 with High-Voltage Controller1-Fan Self-Cleaning ESD Ionizer 7113-Fan Self-Cleaning ESD Ionizer Bar 713
Updated: 2026-10-24
Giao tận nhà máy TP.HCM, Bình Dương, Đồng Nai, Long An, Tây Ninh · Kèm biên bản đo điện trở ESD theo lô · Hotline 0906 108 292