Stocked item: delivered in 1–2 working days in Ho Chi Minh City, Binh Duong and Dong Nai; free delivery for orders from VND 20,000,000; defective items exchanged within 7 days. Shipping & return policy

Product code: ET-TR1380 · Specification: model TR1380, 10³–10¹² Ω, test voltage 10–100 V, LED bar readout, 9 V battery
Surface resistance meter with LED readout
Delivery: ordered item, 7–15 days; quantity and lead time are confirmed with the quotation.
Looking for a pocket ESD surface resistance tester for quick daily checks in your Vietnam factory? The TR1380 is an automatic surface resistance meter with an LED bar readout, compact at 132 × 75 × 35 mm and 110 g. Place it on a mat, worktop, floor, bag or bin and read the resistance range immediately — ideal for QC, IQC and maintenance quick checks every day.
With the built-in electrode the result is in Ω/square; with the external 5 lb electrodes plugged in the result is in Ω, allowing point-to-point, surface-to-ground and volume resistance measurements.
Technical specifications
| Display | LED bar, automatic measurement |
|---|---|
| Resistance range | 10³–10¹² Ω |
| Resistivity range | 10³–10¹² (catalogue prints the unit as Ω/M²) |
| Test voltage | 10–100 V |
| Accuracy | Conductive range 10 %; dissipative range 25 % |
| Built-in electrode | Parallel electrode per DIN EN 100 015/1 and ANSI/ESDA S11.11 |
| External electrodes | Works with 5 lb electrodes per IEC 61340-4-1, ANSI/ESDA S4.1 and S7.1; when external electrodes are plugged in, the built-in electrode is disabled |
| Power | 9 V battery |
| Dimensions | 132 × 75 × 35 mm |
| Weight | 110 g (without battery) |
| Housing | ESD-safe ABS, black |
Data according to the manufacturer’s catalogue.
When to choose the surface resistance meter with LED readout
- You only need to know which range a material falls into (conductive, dissipative, insulative) for a quick on-the-spot check → TR1380: compact, read by LEDs.
- You need actual readings for logbooks and reports, with temperature and humidity at the time of measurement → TR1800 digital surface resistance meter.
- You need to test worktops and floors to S4.1 / S7.1 at 2 test voltages with ±3 % accuracy → TR1801 analog (needle) resistance meter.
- Testing mats and worktops to S4.1 requires 5 lb electrodes, measuring to ground at 10 V; if the result is 1×10⁶ Ω or higher, switch to 100 V and measure again. The TR1380 has a test voltage of 10–100 V and accepts external 5 lb electrodes.
On-site testing service
Before buying a meter, your plant can book free on-site ESD resistance testing: PRIMEAG uses a digital meter with two 5 lb electrodes to measure worktops, floors, mats, trolleys, chairs, racks, trays and bins, and sends a report of the readings for each location. Results are for reference only and cannot be used as audit documentation.
Ordering
MOQ 1. Send the model, quantity and your measurement needs (materials, the standard your plant applies); calibration (12-month certificate) can be included on request. To buy the same type you already use: send a photo of the meter’s label.
Delivery: ordered item, 7–15 days; quantity and lead time are confirmed with the quotation.
Quotation within 30 minutes · Hotline/Zalo +84 906 108 292 · email info@primeag.vn · Mon–Sat, 8:00–17:00.
English: surface resistance meter, ESD resistance tester, LED surface resistivity meter
한국어: 표면저항 측정기, 표면저항계
日本語: 表面抵抗計, 表面抵抗測定器
Frequently asked questions
Is an LED readout good enough for recording results in a log?
The LEDs show the resistance range, which is enough for a quick pass/fail check. If you need actual figures for reports, use the TR1800 digital meter.
Built-in electrode or 5 lb electrodes – what is the difference?
The built-in electrode gives results in Ω/square (surface resistance). The external 5 lb electrodes give results in Ω: point-to-point, surface-to-ground, volume resistance — the method used for S4.1 and S7.1.
What should I watch out for after measuring?
According to the catalogue: after measuring, unplug the cable and store the external electrodes. Do not test a worktop right after wiping it with a cleaning solution.
See the overview page wrist strap testers and resistance meters · same group: Digital surface resistance meter with temperature & humidity, Analog (needle) surface resistance meter.
Price: from 1,056,000 VND (excl. 8% VAT).
REQUEST A QUOTE: send the quantity and specifications you need — PRIMEAG quotes within 30 minutes.
Hotline/Zalo +84 906 108 292 · info@primeag.vn
Written by the PRIMEAG engineering team.
Related guides:TR1800 Resistance Meter Readings Jumping Around: Causes and Fixes
Related products:Walking Test Kit for Body Voltage (TE1023WTS)Ionizer Test Kit with Charged Plate (TE1022CPS / TE1023CPS)Handheld Electrostatic Voltmeter (TE1003)Digital Surface Resistance Meter with Temperature & Humidity
Updated: 2026-10-24
Giao tận nhà máy TP.HCM, Bình Dương, Đồng Nai, Long An, Tây Ninh · Kèm biên bản đo điện trở ESD theo lô · Hotline 0906 108 292