RoHS, Halogen-Free, REACH and ESD Test Reports for Cleanroom Consumables in Vietnam – PRIMEAG
Purchasing and QA teams at electronics factories usually need 3 types of documents when approving a cleanroom consumables supplier: RoHS (10 restricted substances under Directive (EU) 2015/863), Halogen-free (Cl, Br per IEC 61249-2-21) or REACH SVHC, and for ESD items, resistance readings measured to ANSI/ESD or EN methods. The tables below group the reports PRIMEAG currently holds by product group.
How to read: ND = not detected (below the laboratory’s detection limit). The 10 RoHS substances are Pb, Cd, Hg, Cr(VI), PBB, PBDE, DEHP, BBP, DBP, DIBP. Test results apply only to the samples submitted for testing, as stated on each report.
Cleanroom nitrile gloves
| Test | Laboratory · report no. · date | Key results | File |
|---|---|---|---|
| Shirudo – RoHS 10 substances | SGS Shenzhen No. SZXEC23001548505 · 18/07/2023 | 12-inch cleanroom nitrile gloves (sample SFC 12″): Pb, Cd, Hg, Cr(VI), PBB, PBDE, DEHP, BBP, DBP, DIBP all not detected (ND) | Download PDF |
| Nitrilstat – RoHS 10 substances | SGS Malaysia No. CPPG/220486394-CA89315 · 26/04/2022 | Cleanroom nitrile gloves (lot N80): all 10 RoHS substances ND | Download PDF |
| ASAP – RoHS 10 substances | Eurofins NM Laboratory (Malaysia) No. AR-22-SV-043566-01 · 15/06/2022 | Powder-free nitrile gloves 5 mil: Comply – all 10 RoHS substances ND | Download PDF |
See product: Cleanroom nitrile gloves
ESD shielding bags
| Test | Laboratory · report no. · date | Key results | File |
|---|---|---|---|
| RoHS 10 substances + Halogen (F, Cl, Br, I) | SGS Vietnam (VILAS 237) No. VNHL2508028191EE · 05/09/2025 | VMPET/CPP shielding film: PASS RoHS; F, Cl, Br, I all ND | Download PDF |
| RoHS 10 substances | SGS Vietnam (VILAS 237) No. VNHL2309023718EE · 22/09/2023 | SMPET/LLDPE shielding film: Comply – 10 substances ND | Download PDF |
| Technical data sheet (TDS), MGE37-75 film | Declared by the manufacturer No. TDS MGE37-75 · 12/12/2023 | Thickness 75 µm ±10%; inner/outer surface resistance 10⁶–10⁹ Ω (ANSI/ESD S11.11); tensile strength ≥35 MPa; seal strength ≥25 N | Download PDF |
See product: ESD shielding bags
ESD rubber mats
| Test | Laboratory · report no. · date | Key results | File |
|---|---|---|---|
| Two-point resistance (ANSI/ESD STM11.13-2021) | SGS Guangzhou No. GZMR231103286004 · 21/11/2023 | Green mat: 6 samples 4.50–6.34×10⁸ Ω, average 5.12×10⁸ Ω – within the dissipative range of 10⁶–10⁹ Ω | Download PDF |
| RoHS 10 substances | SGS Guangzhou No. CANEC23005067502 · 29/06/2023 | Complies with RoHS (EU) 2015/863: heavy metals, PBB, PBDE ND; DBP 104 mg/kg (limit 1,000) | Download PDF |
See product: ESD rubber mats
Polyester cleanroom wipers 1009SLE
| Test | Laboratory · report no. · date | Key results | File |
|---|---|---|---|
| RoHS 10 substances | SGS Shenzhen No. SZXEC23002744105 · 10/11/2023 | Polyester cleanroom wipers: Pass – 10 substances ND | Download PDF |
| MSDS – wiper 1009SLE | Manufacturer’s data MSDS 1009SLE | 100 % polyester (CAS 27083-59-9), non-hazardous to health | Download PDF |
See product: Polyester cleanroom wipers 1009SLE
Microfiber wipers
| Test | Laboratory · report no. · date | Key results | File |
|---|---|---|---|
| REACH SVHC (223 substances) | SGS Guangzhou No. CANEC2206410201 · 19/04/2022 | Microfiber fabric (samples 8008, 4009, 3109, 3009): PASS – no SVHC above 0.1% | Download PDF |
| RoHS 10 substances + Halogen | SGS Guangzhou No. CANEC2022891001 · 29/12/2020 | Polyester–nylon knitted fabric: Comply RoHS; F, Cl, Br, I all ND | Download PDF |
| MSDS – wiper 8009 | Manufacturer’s data MSDS 8009 | 70 % polyester + 30 % polyamide, non-hazardous to health | Download PDF |
See product: Microfiber wipers
Cleanroom wiping paper / SMT stencil wiping rolls (polycellulose)
| Test | Laboratory · report no. · date | Key results | File |
|---|---|---|---|
| RoHS 10 substances | SGS Shenzhen No. SZXEC23002744101 · 10/11/2023 | Polycellulose wiping paper: Pass – 10 substances ND | Download PDF |
| Halogen (EN 14582) | SGS Guangzhou No. CANEC23005275601 · 04/07/2023 | F, Br, I not detected; Cl 73 mg/kg (halogen-free threshold per IEC 61249-2-21: ≤900) | Download PDF |
| TDS – roll 340 × 530 mm × 9 m | Manufacturer’s data TDS | 55 % cellulose / 45 % polyester, 56 ± 5 g/m², LPC (≥0.5 µm) < 8,000 counts/cm², absorption ≥ 280 mL/m², plastic core Ø19.6 mm U-cut | Download PDF |
| TDS – roll 350 × 500 mm × 7 m | Manufacturer’s data TDS | Same material; plain plastic core Ø19.56 / 13.08 mm | Download PDF |
| TDS – roll 380 × 448 mm × 22 m | Manufacturer’s data TDS | Same material; plastic core Ø10 / 7.5 mm | Download PDF |
See product: Cleanroom wiping paper / SMT stencil wiping rolls (polycellulose) · SMT stencil wiper rolls
ESD PVC curtains / grid curtains
| Test | Laboratory · report no. · date | Key results | File |
|---|---|---|---|
| Two-point resistance (ANSI/ESD STM11.13-2021) | SGS Guangzhou No. GZMR231103286005 · 24/11/2023 | ESD grid curtain: 6 samples 2.30–4.62×10⁵ Ω, average 3.65×10⁵ Ω | Download PDF |
See product: ESD PVC curtains / grid curtains
Cleanroom sticky mats
| Test | Laboratory · report no. · date | Key results | File |
|---|---|---|---|
| RoHS 10 substances | SGS Guangzhou No. CANEC23001931001 · 23/04/2023 | Adhesive dust-removal film: all 10 RoHS substances ND | Download PDF |
| SDS (safety data sheet) – sticky mat | Prepared by SGS Guangzhou per REACH 1907/2006 No. CANHG2311877301 · 21 Jul 2023 | PE film + acrylic adhesive: not classified as hazardous under CLP 1272/2008 | Download PDF |
See product: Cleanroom sticky mats
ESD cleanroom PVC shoes
| Test | Laboratory · report no. · date | Key results | File |
|---|---|---|---|
| Antistatic footwear EN ISO 20347:2012 | SGS Guangzhou (footwear lab) No. SL92219280304501FW · 20/07/2022 | PASS “Antistatic footwear”: dry 51.0–53.7 MΩ, wet 1.8–3.9 MΩ (requirement 0.1–1,000 MΩ) | Download PDF |
See product: ESD cleanroom PVC shoes
Cleanroom printing paper
| Test | Laboratory · report no. · date | Key results | File |
|---|---|---|---|
| RoHS 10 substances | SGS Guangzhou No. CANEC23000148301 · 14/02/2023 | Cleanroom printing paper: all 10 RoHS substances ND | Download PDF |
See product: Cleanroom printing paper
ESD carbon-stripe fabric
| Test | Laboratory · report no. · date | Key results | File |
|---|---|---|---|
| RoHS 10 substances | SGS Guangzhou No. CANEC23003355205 · 24/05/2023 | ESD fabric: Pass – 10 substances ND | Download PDF |
See product: ESD carbon-stripe fabric
Rubber finger cots
| Test | Laboratory · report no. · date | Key results | File |
|---|---|---|---|
| RoHS 10 substances | CPST – Eurones Products Testing (Dongguan) No. C230522074001-1 · 24/05/2023 | Latex finger cots (white, black, pink, yellow): all 10 RoHS substances ND | Download PDF |
See product: Rubber finger cots
Carbon PU-coated ESD gloves
| Test | Laboratory · report no. · date | Key results | File |
|---|---|---|---|
| RoHS 2011/65/EU – phthalates (DEHP, BBP, DBP, DIBP) | FITI Testing & Research Institute (Daegu, Korea) No. T270-17-00951 · 15 Mar 2017 | Carbon fingertip PU-coated gloves: DEHP, BBP, DBP, DIBP all <0.01 % (below detection limit) | Download PDF |
| RoHS 2011/65/EU – PBBs, PBDEs | FITI Testing & Research Institute (Daegu, Korea) No. T285-14-00186 · 23 Jul 2014 | Carbon palm PU-coated gloves: all 10 PBBs and 10 PBDEs not detected (GC-MSD, limit 1 mg/kg) | Download PDF |
| MSDS – carbon polyester yarn | Yarn manufacturer’s data No. CF-32 · Jul 2018 | Carbon polyester filament: non-hazardous, yarn resistance approx. 10⁶ Ω/cm | Download PDF |
See product: Carbon Top PU fingertip gloves · Carbon Palm PU gloves
Non-woven shoe covers
| Test | Laboratory · report no. · date | Key results | File |
|---|---|---|---|
| Textile safety GB 18401-2010 (class B) | GTTC – Guangzhou Textile Testing Center No. 200175984 · 16 Jul 2020 | Non-woven shoe covers: pH 6.4 (4.0–8.5 required); formaldehyde not detected (≤75 mg/kg); no abnormal odour; colour fastness to perspiration/water grade 4–4.5 | Download PDF |
See product: Cleanroom head covers & shoe covers
SMT splice clips (copper)
| Test | Laboratory · report no. · date | Key results | File |
|---|---|---|---|
| RoHS – Pb, Hg, Cd, Cr(VI) | SGS Guangzhou No. CANEC2217498002 · 18 Aug 2022 | SMT splice clip model M0700: PASS – Pb, Hg, Cd and Cr(VI) all ND | Download PDF |
See guide: ESD supplies for SMT lines
Cobalt-free humidity indicator cards (HIC)
| Test | Laboratory · report no. · date | Key results | File |
|---|---|---|---|
| Specification – 6-spot card (10–60 %) | Manufacturer’s data (Korea) Spec CDF-HIC | Cobalt dichloride free, no REACH SVHC, none of the 6 RoHS substances; blue → pink; meets IPC/JEDEC J-STD-033 | Download PDF |
| Specification – 6-spot card (brown → green) | Manufacturer’s data (Korea) Spec CDF-HIC | Cobalt dichloride free, no SVHC, none of the 6 RoHS substances; meets IPC/JEDEC J-STD-033 | Download PDF |
| MSDS | Manufacturer’s data No. AA01290-0000000002 · 2021 | GHS: self-heating (H251), eye/respiratory irritant; store cool and dry, do not ingest | Download PDF |
See product: Silica gel desiccant & humidity cards
Why is some information on the reports masked?
The sample submitter and manufacturer details on the reports are masked to protect the supply chain. Report number, laboratory name, test, issue date and results are kept unchanged. PRIMEAG provides the full (unmasked) version to customers on request as part of a supplier qualification file or together with a quotation or contract.
Need actual resistance readings for the ESD materials already in use on your shop floor? See the free on-site ESD resistance testing at your factory (Ho Chi Minh City, Binh Duong, Dong Nai). When you buy under a supply contract, each batch comes with measurement report PAG-QA-ESD-01 made with a calibrated meter.
Frequently asked questions
Does PRIMEAG have RoHS test reports for cleanroom nitrile gloves in Vietnam?
Yes. PRIMEAG holds RoHS 10-substance test reports for 3 cleanroom nitrile glove lines: Shirudo (SGS, No. SZXEC23001548505, 18/07/2023), Nitrilstat (SGS Malaysia, No. CPPG/220486394-CA89315, 26/04/2022) and ASAP (Eurofins, No. AR-22-SV-043566-01, 15/06/2022). All 10 substances were not detected.
Are PRIMEAG ESD shielding bags halogen-free, and is there a test report?
Yes. SGS Vietnam report No. VNHL2508028191EE dated 05/09/2025 for VMPET/CPP shielding film: passes RoHS 10 substances, and F, Cl, Br, I were all not detected. The TDS for MGE37-75 film states a surface resistance of 10⁶–10⁹ Ω per ANSI/ESD S11.11.
Is there a lab test report for the resistance of ESD rubber mats?
Yes. SGS Guangzhou (No. GZMR231103286004, 21/11/2023) measured two-point resistance per ANSI/ESD STM11.13-2021: average 5.12×10⁸ Ω, within the dissipative range of 10⁶–10⁹ Ω. The mat also has SGS RoHS report No. CANEC23005067502.
Why are company names blacked out on the test reports published online?
The names of the sample submitter and the manufacturer are masked to protect the supply chain. Report number, laboratory, issue date and results are kept unchanged for verification. The full version is sent to customers on request.
How can I get a certificate pack for supplier qualification or audit?
Send the product name and the list of documents you need (RoHS, halogen, REACH, MSDS, TDS, CO) via the contact form or Zalo 0906 108 292. PRIMEAG sends the files within the working day and a quote within 30 minutes.
Mon–Sat, 8:00–17:00 (GMT+7) · Phone/Zalo: +84 906 108 292 · Email: info@primeag.vn
Start where it suits you: Free technical advice · Send a drawing or layout · Get a quote within 30 minutes
Written by the PRIMEAG engineering team
Updated: 21/10/2026 — PRIMEAG engineering team