RoHS, Halogen & REACH Test Reports for Cleanroom Supplies in Vietnam

RoHS, Halogen-Free, REACH and ESD Test Reports for Cleanroom Consumables in Vietnam – PRIMEAG

Quick answer: Looking for RoHS, halogen-free or ESD test reports for cleanroom consumables in Vietnam? PRIMEAG publishes 23 test reports issued by independent laboratories (SGS Vietnam, SGS China, SGS Malaysia, SGS Korea, Eurofins, CPST, FITI, GTTC) and 10 manufacturer documents (TDS, MSDS) for 16 groups of cleanroom and ESD consumables: nitrile gloves, carbon PU-coated gloves, shielding bags, ESD rubber mats, polyester wipers, microfiber wipers, wiping paper, PVC curtains, sticky mats, shoes, shoe covers, printing paper, fabric, finger cots, SMT splice clips and humidity indicator cards. Each report keeps its original report number for verification, and the PDF can be downloaded directly from this page.

Purchasing and QA teams at electronics factories usually need 3 types of documents when approving a cleanroom consumables supplier: RoHS (10 restricted substances under Directive (EU) 2015/863), Halogen-free (Cl, Br per IEC 61249-2-21) or REACH SVHC, and for ESD items, resistance readings measured to ANSI/ESD or EN methods. The tables below group the reports PRIMEAG currently holds by product group.

How to read: ND = not detected (below the laboratory’s detection limit). The 10 RoHS substances are Pb, Cd, Hg, Cr(VI), PBB, PBDE, DEHP, BBP, DBP, DIBP. Test results apply only to the samples submitted for testing, as stated on each report.

Cleanroom nitrile gloves

TestLaboratory · report no. · dateKey resultsFile
Shirudo – RoHS 10 substancesSGS Shenzhen
No. SZXEC23001548505 · 18/07/2023
12-inch cleanroom nitrile gloves (sample SFC 12″): Pb, Cd, Hg, Cr(VI), PBB, PBDE, DEHP, BBP, DBP, DIBP all not detected (ND)Download PDF
Nitrilstat – RoHS 10 substancesSGS Malaysia
No. CPPG/220486394-CA89315 · 26/04/2022
Cleanroom nitrile gloves (lot N80): all 10 RoHS substances NDDownload PDF
ASAP – RoHS 10 substancesEurofins NM Laboratory (Malaysia)
No. AR-22-SV-043566-01 · 15/06/2022
Powder-free nitrile gloves 5 mil: Comply – all 10 RoHS substances NDDownload PDF

See product: Cleanroom nitrile gloves

ESD shielding bags

TestLaboratory · report no. · dateKey resultsFile
RoHS 10 substances + Halogen (F, Cl, Br, I)SGS Vietnam (VILAS 237)
No. VNHL2508028191EE · 05/09/2025
VMPET/CPP shielding film: PASS RoHS; F, Cl, Br, I all NDDownload PDF
RoHS 10 substancesSGS Vietnam (VILAS 237)
No. VNHL2309023718EE · 22/09/2023
SMPET/LLDPE shielding film: Comply – 10 substances NDDownload PDF
Technical data sheet (TDS), MGE37-75 filmDeclared by the manufacturer
No. TDS MGE37-75 · 12/12/2023
Thickness 75 µm ±10%; inner/outer surface resistance 10⁶–10⁹ Ω (ANSI/ESD S11.11); tensile strength ≥35 MPa; seal strength ≥25 NDownload PDF

See product: ESD shielding bags

ESD rubber mats

TestLaboratory · report no. · dateKey resultsFile
Two-point resistance (ANSI/ESD STM11.13-2021)SGS Guangzhou
No. GZMR231103286004 · 21/11/2023
Green mat: 6 samples 4.50–6.34×10⁸ Ω, average 5.12×10⁸ Ω – within the dissipative range of 10⁶–10⁹ ΩDownload PDF
RoHS 10 substancesSGS Guangzhou
No. CANEC23005067502 · 29/06/2023
Complies with RoHS (EU) 2015/863: heavy metals, PBB, PBDE ND; DBP 104 mg/kg (limit 1,000)Download PDF

See product: ESD rubber mats

Polyester cleanroom wipers 1009SLE

TestLaboratory · report no. · dateKey resultsFile
RoHS 10 substancesSGS Shenzhen
No. SZXEC23002744105 · 10/11/2023
Polyester cleanroom wipers: Pass – 10 substances NDDownload PDF
MSDS – wiper 1009SLEManufacturer’s data
MSDS 1009SLE
100 % polyester (CAS 27083-59-9), non-hazardous to healthDownload PDF

See product: Polyester cleanroom wipers 1009SLE

Microfiber wipers

TestLaboratory · report no. · dateKey resultsFile
REACH SVHC (223 substances)SGS Guangzhou
No. CANEC2206410201 · 19/04/2022
Microfiber fabric (samples 8008, 4009, 3109, 3009): PASS – no SVHC above 0.1%Download PDF
RoHS 10 substances + HalogenSGS Guangzhou
No. CANEC2022891001 · 29/12/2020
Polyester–nylon knitted fabric: Comply RoHS; F, Cl, Br, I all NDDownload PDF
MSDS – wiper 8009Manufacturer’s data
MSDS 8009
70 % polyester + 30 % polyamide, non-hazardous to healthDownload PDF

See product: Microfiber wipers

Cleanroom wiping paper / SMT stencil wiping rolls (polycellulose)

TestLaboratory · report no. · dateKey resultsFile
RoHS 10 substancesSGS Shenzhen
No. SZXEC23002744101 · 10/11/2023
Polycellulose wiping paper: Pass – 10 substances NDDownload PDF
Halogen (EN 14582)SGS Guangzhou
No. CANEC23005275601 · 04/07/2023
F, Br, I not detected; Cl 73 mg/kg (halogen-free threshold per IEC 61249-2-21: ≤900)Download PDF
TDS – roll 340 × 530 mm × 9 mManufacturer’s data
TDS
55 % cellulose / 45 % polyester, 56 ± 5 g/m², LPC (≥0.5 µm) < 8,000 counts/cm², absorption ≥ 280 mL/m², plastic core Ø19.6 mm U-cutDownload PDF
TDS – roll 350 × 500 mm × 7 mManufacturer’s data
TDS
Same material; plain plastic core Ø19.56 / 13.08 mmDownload PDF
TDS – roll 380 × 448 mm × 22 mManufacturer’s data
TDS
Same material; plastic core Ø10 / 7.5 mmDownload PDF

See product: Cleanroom wiping paper / SMT stencil wiping rolls (polycellulose) · SMT stencil wiper rolls

ESD PVC curtains / grid curtains

TestLaboratory · report no. · dateKey resultsFile
Two-point resistance (ANSI/ESD STM11.13-2021)SGS Guangzhou
No. GZMR231103286005 · 24/11/2023
ESD grid curtain: 6 samples 2.30–4.62×10⁵ Ω, average 3.65×10⁵ ΩDownload PDF

See product: ESD PVC curtains / grid curtains

Cleanroom sticky mats

TestLaboratory · report no. · dateKey resultsFile
RoHS 10 substancesSGS Guangzhou
No. CANEC23001931001 · 23/04/2023
Adhesive dust-removal film: all 10 RoHS substances NDDownload PDF
SDS (safety data sheet) – sticky matPrepared by SGS Guangzhou per REACH 1907/2006
No. CANHG2311877301 · 21 Jul 2023
PE film + acrylic adhesive: not classified as hazardous under CLP 1272/2008Download PDF

See product: Cleanroom sticky mats

ESD cleanroom PVC shoes

TestLaboratory · report no. · dateKey resultsFile
Antistatic footwear EN ISO 20347:2012SGS Guangzhou (footwear lab)
No. SL92219280304501FW · 20/07/2022
PASS “Antistatic footwear”: dry 51.0–53.7 MΩ, wet 1.8–3.9 MΩ (requirement 0.1–1,000 MΩ)Download PDF

See product: ESD cleanroom PVC shoes

Cleanroom printing paper

TestLaboratory · report no. · dateKey resultsFile
RoHS 10 substancesSGS Guangzhou
No. CANEC23000148301 · 14/02/2023
Cleanroom printing paper: all 10 RoHS substances NDDownload PDF

See product: Cleanroom printing paper

ESD carbon-stripe fabric

TestLaboratory · report no. · dateKey resultsFile
RoHS 10 substancesSGS Guangzhou
No. CANEC23003355205 · 24/05/2023
ESD fabric: Pass – 10 substances NDDownload PDF

See product: ESD carbon-stripe fabric

Rubber finger cots

TestLaboratory · report no. · dateKey resultsFile
RoHS 10 substancesCPST – Eurones Products Testing (Dongguan)
No. C230522074001-1 · 24/05/2023
Latex finger cots (white, black, pink, yellow): all 10 RoHS substances NDDownload PDF

See product: Rubber finger cots

Carbon PU-coated ESD gloves

TestLaboratory · report no. · dateKey resultsFile
RoHS 2011/65/EU – phthalates (DEHP, BBP, DBP, DIBP)FITI Testing & Research Institute (Daegu, Korea)
No. T270-17-00951 · 15 Mar 2017
Carbon fingertip PU-coated gloves: DEHP, BBP, DBP, DIBP all <0.01 % (below detection limit)Download PDF
RoHS 2011/65/EU – PBBs, PBDEsFITI Testing & Research Institute (Daegu, Korea)
No. T285-14-00186 · 23 Jul 2014
Carbon palm PU-coated gloves: all 10 PBBs and 10 PBDEs not detected (GC-MSD, limit 1 mg/kg)Download PDF
MSDS – carbon polyester yarnYarn manufacturer’s data
No. CF-32 · Jul 2018
Carbon polyester filament: non-hazardous, yarn resistance approx. 10⁶ Ω/cmDownload PDF

See product: Carbon Top PU fingertip gloves · Carbon Palm PU gloves

Non-woven shoe covers

TestLaboratory · report no. · dateKey resultsFile
Textile safety GB 18401-2010 (class B)GTTC – Guangzhou Textile Testing Center
No. 200175984 · 16 Jul 2020
Non-woven shoe covers: pH 6.4 (4.0–8.5 required); formaldehyde not detected (≤75 mg/kg); no abnormal odour; colour fastness to perspiration/water grade 4–4.5Download PDF

See product: Cleanroom head covers & shoe covers

SMT splice clips (copper)

TestLaboratory · report no. · dateKey resultsFile
RoHS – Pb, Hg, Cd, Cr(VI)SGS Guangzhou
No. CANEC2217498002 · 18 Aug 2022
SMT splice clip model M0700: PASS – Pb, Hg, Cd and Cr(VI) all NDDownload PDF

See guide: ESD supplies for SMT lines

Cobalt-free humidity indicator cards (HIC)

TestLaboratory · report no. · dateKey resultsFile
Specification – 6-spot card (10–60 %)Manufacturer’s data (Korea)
Spec CDF-HIC
Cobalt dichloride free, no REACH SVHC, none of the 6 RoHS substances; blue → pink; meets IPC/JEDEC J-STD-033Download PDF
Specification – 6-spot card (brown → green)Manufacturer’s data (Korea)
Spec CDF-HIC
Cobalt dichloride free, no SVHC, none of the 6 RoHS substances; meets IPC/JEDEC J-STD-033Download PDF
MSDSManufacturer’s data
No. AA01290-0000000002 · 2021
GHS: self-heating (H251), eye/respiratory irritant; store cool and dry, do not ingestDownload PDF

See product: Silica gel desiccant & humidity cards

Why is some information on the reports masked?

The sample submitter and manufacturer details on the reports are masked to protect the supply chain. Report number, laboratory name, test, issue date and results are kept unchanged. PRIMEAG provides the full (unmasked) version to customers on request as part of a supplier qualification file or together with a quotation or contract.

Need actual resistance readings for the ESD materials already in use on your shop floor? See the free on-site ESD resistance testing at your factory (Ho Chi Minh City, Binh Duong, Dong Nai). When you buy under a supply contract, each batch comes with measurement report PAG-QA-ESD-01 made with a calibrated meter.

Frequently asked questions

Does PRIMEAG have RoHS test reports for cleanroom nitrile gloves in Vietnam?

Yes. PRIMEAG holds RoHS 10-substance test reports for 3 cleanroom nitrile glove lines: Shirudo (SGS, No. SZXEC23001548505, 18/07/2023), Nitrilstat (SGS Malaysia, No. CPPG/220486394-CA89315, 26/04/2022) and ASAP (Eurofins, No. AR-22-SV-043566-01, 15/06/2022). All 10 substances were not detected.

Are PRIMEAG ESD shielding bags halogen-free, and is there a test report?

Yes. SGS Vietnam report No. VNHL2508028191EE dated 05/09/2025 for VMPET/CPP shielding film: passes RoHS 10 substances, and F, Cl, Br, I were all not detected. The TDS for MGE37-75 film states a surface resistance of 10⁶–10⁹ Ω per ANSI/ESD S11.11.

Is there a lab test report for the resistance of ESD rubber mats?

Yes. SGS Guangzhou (No. GZMR231103286004, 21/11/2023) measured two-point resistance per ANSI/ESD STM11.13-2021: average 5.12×10⁸ Ω, within the dissipative range of 10⁶–10⁹ Ω. The mat also has SGS RoHS report No. CANEC23005067502.

Why are company names blacked out on the test reports published online?

The names of the sample submitter and the manufacturer are masked to protect the supply chain. Report number, laboratory, issue date and results are kept unchanged for verification. The full version is sent to customers on request.

How can I get a certificate pack for supplier qualification or audit?

Send the product name and the list of documents you need (RoHS, halogen, REACH, MSDS, TDS, CO) via the contact form or Zalo 0906 108 292. PRIMEAG sends the files within the working day and a quote within 30 minutes.

PRIMEAG Co., Ltd. – Room 10, Mezzanine, Dai Thanh Binh Building, 911-913-915-917 Nguyen Trai, Cho Lon Ward, Ho Chi Minh City, Vietnam
Mon–Sat, 8:00–17:00 (GMT+7) · Phone/Zalo: +84 906 108 292 · Email: info@primeag.vn
Start where it suits you: Free technical advice · Send a drawing or layout · Get a quote within 30 minutes
Written by the PRIMEAG engineering team

Updated: 21/10/2026 — PRIMEAG engineering team